JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
man pages section 1M: System Administration Commands     Oracle Solaris 11.1 Information Library
search filter icon
search icon

Document Information

Preface

Introduction

System Administration Commands - Part 1

System Administration Commands - Part 2

luxadm(1M)

mail.local(1M)

makedbm(1M)

makemap(1M)

masfcnv(1M)

mdlogd(1M)

mdmonitord(1M)

mdnsd(1M)

medstat(1M)

metaclear(1M)

metadb(1M)

metadetach(1M)

metadevadm(1M)

metahs(1M)

metaimport(1M)

metainit(1M)

metaoffline(1M)

metaonline(1M)

metaparam(1M)

metarecover(1M)

metarename(1M)

metareplace(1M)

metaset(1M)

metassist(1M)

metastat(1M)

metasync(1M)

metattach(1M)

mib2mof(1M)

mibiisa(1M)

mkbootmedia(1M)

mkdevalloc(1M)

mkdevmaps(1M)

mkfifo(1M)

mkfile(1M)

mkfs(1M)

mkfs_pcfs(1M)

mkfs_udfs(1M)

mkfs_ufs(1M)

mknod(1M)

mkntfs(1M)

mkpwdict(1M)

modinfo(1M)

modload(1M)

modunload(1M)

mofcomp(1M)

mofreg(1M)

monacct(1M)

monitor(1M)

mount(1M)

mountall(1M)

mountd(1M)

mount_hsfs(1M)

mount_nfs(1M)

mount_pcfs(1M)

mount_smbfs(1M)

mount_tmpfs(1M)

mount_udfs(1M)

mount_ufs(1M)

mpathadm(1M)

mpstat(1M)

msgid(1M)

mvdir(1M)

named(1M)

named-checkconf(1M)

named-checkzone(1M)

named-compilezone(1M)

ncaconfd(1M)

ncheck(1M)

ncheck_ufs(1M)

ndd(1M)

ndmpadm(1M)

ndmpd(1M)

ndmpstat(1M)

netadm(1M)

netcfg(1M)

netcfgd(1M)

netservices(1M)

netstat(1M)

netstrategy(1M)

newaliases(1M)

newfs(1M)

newkey(1M)

nfs4cbd(1M)

nfsd(1M)

nfslogd(1M)

nfsmapid(1M)

nfsref(1M)

nfsstat(1M)

nscadm(1M)

nscd(1M)

nscfg(1M)

nsdb-list(1M)

nsdb-nces(1M)

nsdbparams(1M)

nsdb-resolve-fsn(1M)

nsdb-update-nci(1M)

nslookup(1M)

nsupdate(1M)

ntfscat(1M)

ntfsclone(1M)

ntfscluster(1M)

ntfscmp(1M)

ntfscp(1M)

ntfsfix(1M)

ntfsinfo(1M)

ntfslabel(1M)

ntfsls(1M)

ntfsprogs(1M)

ntfsresize(1M)

ntfsundelete(1M)

nulladm(1M)

nwamd(1M)

obpsym(1M)

oplhpd(1M)

pageout(1M)

parted(1M)

pbind(1M)

pcitool(1M)

pfedit(1M)

pginfo(1M)

pgstat(1M)

picld(1M)

ping(1M)

pkg2du(1M)

pkgadd(1M)

pkgadm(1M)

pkgask(1M)

pkgchk(1M)

pkgcond(1M)

pkg.depotd(1M)

pkgrm(1M)

pkg.sysrepo(1M)

plockstat(1M)

pntadm(1M)

polkit-is-privileged(1M)

pooladm(1M)

poolbind(1M)

poolcfg(1M)

poold(1M)

poolstat(1M)

ports(1M)

poweradm(1M)

poweroff(1M)

powertop(1M)

pppd(1M)

pppoec(1M)

pppoed(1M)

pppstats(1M)

praudit(1M)

prctmp(1M)

prdaily(1M)

projadd(1M)

projdel(1M)

projmod(1M)

prstat(1M)

prtacct(1M)

prtconf(1M)

prtdiag(1M)

prtdscp(1M)

prtfru(1M)

prtpicl(1M)

prtvtoc(1M)

psradm(1M)

psrinfo(1M)

psrset(1M)

pwck(1M)

pwconv(1M)

quot(1M)

quota(1M)

quotacheck(1M)

quotaoff(1M)

quotaon(1M)

rad(1M)

raidctl(1M)

ramdiskadm(1M)

rarpd(1M)

rcapadm(1M)

rcapd(1M)

rctladm(1M)

rdate(1M)

rdisc(1M)

reboot(1M)

rem_drv(1M)

remove_allocatable(1M)

removef(1M)

reparsed(1M)

repquota(1M)

restricted_shell(1M)

rexd(1M)

rexecd(1M)

rlogind(1M)

rmmount(1M)

rmt(1M)

rmvolmgr(1M)

rndc(1M)

rndc-confgen(1M)

roleadd(1M)

roledel(1M)

rolemod(1M)

root_archive(1M)

route(1M)

routeadm(1M)

routed(1M)

rpcbind(1M)

rpc.bootparamd(1M)

rpcinfo(1M)

rpc.mdcommd(1M)

rpc.metad(1M)

rpc.metamedd(1M)

rpc.metamhd(1M)

rpc.rexd(1M)

rpc.rstatd(1M)

rpc.rusersd(1M)

rpc.rwalld(1M)

rpc.smserverd(1M)

rpc.sprayd(1M)

rpc.yppasswdd(1M)

rpc.ypupdated(1M)

rquotad(1M)

rsh(1M)

rshd(1M)

rstatd(1M)

rtc(1M)

rtquery(1M)

runacct(1M)

rusersd(1M)

rwall(1M)

rwalld(1M)

rwhod(1M)

sa1(1M)

sa2(1M)

sadc(1M)

sar(1M)

sasinfo(1M)

savecore(1M)

sbdadm(1M)

sched(1M)

sckmd(1M)

scmadm(1M)

sconadm(1M)

sendmail(1M)

sftp-server(1M)

shadowd(1M)

shadowstat(1M)

share(1M)

shareall(1M)

sharectl(1M)

share_nfs(1M)

share_smb(1M)

showmount(1M)

shutacct(1M)

shutdown(1M)

slpd(1M)

smattrpop(1M)

smbadm(1M)

smbd(1M)

smbiod(1M)

smbiod-svc(1M)

smbios(1M)

smbstat(1M)

smrsh(1M)

smtp-notify(1M)

sndradm(1M)

sndrd(1M)

sndrsyncd(1M)

snmpdx(1M)

snmp-notify(1M)

snmpXwbemd(1M)

snoop(1M)

soconfig(1M)

soladdapp(1M)

soldelapp(1M)

solstice(1M)

sppptun(1M)

spray(1M)

sprayd(1M)

srptadm(1M)

sshd(1M)

ssh-keysign(1M)

startup(1M)

statd(1M)

stclient(1M)

stmfadm(1M)

stmsboot(1M)

strace(1M)

strclean(1M)

strerr(1M)

sttydefs(1M)

su(1M)

sulogin(1M)

suriadm(1M)

svadm(1M)

svcadm(1M)

svcbundle(1M)

svccfg(1M)

svc.configd(1M)

svc.ipfd(1M)

svc.startd(1M)

swap(1M)

sxadm(1M)

sync(1M)

syncinit(1M)

syncloop(1M)

syncstat(1M)

sysconfig(1M)

sysdef(1M)

syseventadm(1M)

syseventconfd(1M)

syseventd(1M)

syslogd(1M)

talkd(1M)

tapes(1M)

telnetd(1M)

tftpd(1M)

th_define(1M)

th_manage(1M)

tic(1M)

tncfg(1M)

tnchkdb(1M)

tnctl(1M)

tnd(1M)

tninfo(1M)

tpmadm(1M)

traceroute(1M)

trapstat(1M)

ttymon(1M)

tunefs(1M)

turnacct(1M)

txzonemgr(1M)

tzreload(1M)

tzselect(1M)

uadmin(1M)

ucodeadm(1M)

ufsdump(1M)

ufsrestore(1M)

umount(1M)

umountall(1M)

System Administration Commands - Part 3

sasinfo

- Serial Attached SCSI HBA port command line interface

Synopsis

sasinfo hba [-v] [HBA_Name]...
sasinfo hba-port [-lvy] [-a HBA_Name] [HBA_port_nam]...
sasinfo expander [-vt] [-p HBA_port_Name] [Expander_SAS_Addr]...
sasinfo target-port [-s | -v] [Target_port_SAS_Addr]...
sasinfo logical-unit | lu [-v] [device_path]...
sasinfo [-V]
sasinfo [-?]

Description

The sasinfo utility is a command line interface that collects administrative information on Serial Attached SCSI–2 (SAS–2) host bus adapter (HBA) that supports the Storage Management HBA API (SM-HBA). The utility reports attributes of HBA ports and of expander devices and SCSI target devices that might be connected to those HBA ports.

sasinfo is implemented as a set of subcommands, described below.

Sub-commands

The following subcommands are supported by sasinfo.

hba

Lists information for the HBA referenced by the specified HBA_name. If HBA_name is not specified, all HBAs on the host will be listed.

hba-port

Lists information for the HBA port referenced by the specified HBA_port_Name. If HBA_port_Name is not specified, all HBA ports on the host will be listed. Note that HBA ports can be dynamically configured/unconfigured so that the number of HBA ports on an HBA can change as connections to target devices are established. With no connections to a storage device, no HBA port is configured.

expander

Lists hierarchical view of the expander referenced by the specified Expander_SAS_Addr. If no argument is specified, all expanders that are visible across all HBA ports on the host will be listed.

target-port

Lists information for those target ports referenced by Target_port_SAS_Addr address. If no argument is specified, all target ports that are visible on the host will be listed.

logical-unit | lu

Lists the logical unit referenced by the specified device_path. If device_path is not specified, all SAS logical units will be listed, including the SAS Management Protocol (SMP) target port.

Options

The following options are supported.

-?, --help

Displays usage information

-a, --hba HBA_Name

Retrieve HBA port information from the HBA_Name of an HBA on the host. The -a option can only be used with the hba-port subcommand.

-l, --phy-linkstat

Lists the link error statistics information for the phys on the HBA port referenced by the specified HBA_port_Name or all HBA ports if no HBA port is specified. This option is used only with the hba-port subcommand.

-p HBA_port_SAS_Addr, --port HBA_port_SAS_Addr

Retrieve remote port information from the HBA_port_SAS_Addr of the local HBA port on the host. The -p option can be used only with the expander subcommand.

-s, --scsi

Lists SCSI attributes for target ports that are requested for display. This option is only used for the target-port subcommand.

-v, --verbose

Display details on hardware information, such as SAS address, topology device, and so forth, based on which subcommand is invoked.

-V, --version

Displays the version information.

-y, --phy

Lists the phy information on the HBA port specified by HBA_port_Name or all HBA ports if no HBA port is specified. This option is used only with the hba-port subcommand.

Examples

Example 1 Listing All HBAs

The following command lists all HBAs on the host.

# sasinfo hba
HBA Name: SUNW-pmcs-0
HBA Name: SUNW-pmcs-1

Example 2 Listing All HBAs with Details

The following command lists all HBAs on the host, along with related details. Note that each HBA has two HBA ports configured, with each HBA port connected to a storage device.

# sasinfo hba -v
HBA Name: SUNW-pmcs-0
    Manufacturer: sun
    Model: SAS Gen-2
    Firmware Version: 1.1
    FCode/BIOS Version: 1.1
    Serial Number: 111-11111
    Driver Name: smvsl
    Driver Version: 1.1
    Number of HBA Ports: 2
HBA Name: SUNW-pmcs-1
    Manufacturer: sun
    Model: SAS Gen-2
    Firmware Version: 1.1
    FCode/BIOS Version: 1.1
    Serial Number: 111-11111
    Driver Name: smvsl
    Driver Version: 1.1
    Number of HBA Ports: 2

Example 3 Listing All HBA Ports

The following command lists all HBA ports on the host.

# sasinfo hba-port
HBA Name: SUNW-pmcs-0
    HBA Port Name: /dev/cfg/c1
    HBA Port Name: /dev/cfg/c2
HBA Name: SUNW-pmcs-1
    HBA Port Name: /dev/cfg/c3
    HBA Port Name: /dev/cfg/c4

Example 4 Listing all HBA Ports with Details

The following command lists all HBA ports, with accompanying details.

# sasinfo hba-port -v
HBA Name: SUNW-pmcs-0
    HBA Port Name: /dev/cfg/c1
        Type: sas-device
        State: online
        Local SAS Address: 5000c50000d756aa
        Attached Port SAS Address: 50800201a5a502bf
        Number of Phys: 4
    HBA Port Name: /dev/cfg/c25000c50000d756cc
        Type: sas-device
        State: online
        Local SAS Address: 5000c50000d756aa
        Attached Port SAS Address: 50800201a5a503bf
        Number of Phys: 4
HBA Name: SUNW-pmcs-1
    HBA Port Name: /dev/cfg/c3
        Type: sas-device
        State: online
        Local SAS Address: 5000c50000d756cc
        Attached Port SAS Address: 50800201a5a504bf
        Number of Phys: 4
    HBA Port Name: /dev/cfg/c4
        Type: sas-device
        State: online
        Local SAS Address: 5000c50000d756cc
        Attached Port SAS Address: 50800201a5a505bf
        Number of Phys: 4

Example 5 Listing phy Information for All HBA Ports

The following command lists phy information for all HBA ports.

# sasinfo hba-port -y
HBA Name: SUNW-pmcs-0
    HBA Port Name: /dev/cfg/c1
        Phy Information:
         Identifier: 0
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 1
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 2
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 3
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
    HBA Port Name: /dev/cfg/c2
        Phy Information:
         Identifier: 4
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 5
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
        Identifier: 6
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
        Identifier: 7
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
HBA Name: SUNW-pmcs-1
    HBA Port Name: /dev/cfg/c3
        Phy Information:
         Identifier: 0
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 1
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 2
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 3
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
    HBA Port Name: /dev/cfg/c4
        Phy Information:
         Identifier: 4
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 5
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 6
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit
         Identifier: 7
           State: enabled
           HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
           ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
           NegotiatedLinkRate: 3Gbit

Example 6 Listing phy Link Error Statistics for a Specific HBA Port

The following command lists phy link error statistics for a particular port.

# sasinfo hba-port -ly /dev/cfg/c1
HBA Name: SUNW-pmcs-0
  HBA Port Name: /dev/cfg/c1
    Phy Information:
      Identifier: 0
       State: enabled
         HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
         ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
         NegotiatedLinkRate: 3Gbit
         Link Error Statistics:
           Invalid Dword: 0
           Running Disparity Error: 0
           Loss of Dword Sync: 0
           Reset Problem: 0
      Identifier: 1
         State: enabled
         HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
         ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
         NegotiatedLinkRate: 3Gbit
         Link Error Statistics:
           Invalid Dword: 0
           Running Disparity Error: 0
           Loss of Dword Sync: 0
           Reset Problem: 0
       Identifier: 2
          State: enabled
          HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
          ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
          NegotiatedLinkRate: 3Gbit
          Link Error Statistics:
            Invalid Dword: 0
            Running Disparity Error: 0
            Loss of Dword Sync: 0
            Reset Problem: 0
       Identifier: 3
          State: enabled
          HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
          ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
          NegotiatedLinkRate: 3Gbit
          Link Error Statistics:
            Invalid Dword: 0
            Running Disparity Error: 0
            Loss of Dword Sync: 0
            Reset Problem: 0

Example 7 Listing Expanders Connected to an HBA Port

The following command lists all expanders that are visible through the specified HBA port.

# sasinfo expander -p /dev/cfg/c1
HBA Name: SUNW-pmcs-0
  HBA Port Name: /dev/cfg/c1
    Expander SAS Address(Tier 1): 50800201a5a502bf
       Expander SAS Address(Tier 2): 50800201a5a50233
       Expander SAS Address(Tier 2); 5000c5000d2da812
    Expander SAS Address(Tier 1): 50800201a5a503bf
       Expander SAS Address(Tier 2): 50800201a5a502d2
       Expander SAS Address(Tier 2); 5000c5000d2da823

Example 8 Listing Detailed Information on Expanders

The following command lists detailed information on all expanders that are visible through the specified HBA port.

# sasinfo expander -v -p /dev/cfg/c1
HBA Name: SUNW-pmcs-0
  HBA Port Name: /dev/cfg/c1
    Expander SAS Address(Tier 1): 50800201a5a502bf
      OS Device Name: /dev/smp/expd0
      State: online
        Expander SAS Address(Tier 2): 50800201a5a50233
          OS Device Name: /dev/smp/expd2
          State: online
        Expander SAS Address(Tier 2); 5000c5000d2da812
          OS Device Name: /dev/smp/expd3
          State: online
    Expander SAS Address(Tier 1): 50800201a5a503bf
      OS Device Name: /dev/smp/expd1
      State: online
        Expander SAS Address(Tier 2): 50800201a5a502d2
          OS Device Name: /dev/smp/expd3
          State: online
        Expander SAS Address(Tier 2); 5000c5000d2da823
          OS Device Name: /dev/smp/expd4
          State: online

Example 9 Listing Target Ports Attached to Expanders

The following command lists all target ports that are attached to expanders connected to a specified HBA port.

# sasinfo expander -t -p /dev/cfg/c1
HBA Name: SUNW-pmcs-0
  HBA Port Name: /dev/cfg/c1
     Expander SAS Address(Tier 1): 50800201a5a502bf
       Target Port SAS Address: 50800201a5a504f1
          Expander SAS Address(Tier 2): 50800201a5a50233
            Target Port SAS Address: 50800201a5a502be
            Target Port SAS Address: 5000c5000d2da8b2
          Expander SAS Address(Tier 2); 5000c5000d2da812
            Target Port SAS Address: 50800201a5a502be
            Target Port SAS Address: 50800201a5a508b2
     Expander SAS Address(Tier 1): 50800201a5a503bf
       Target Port SAS Address: 50800201a5a50421
          Expander SAS Address(Tier 2): 50800201a5a502d2
            Target Port SAS Address: 50800201a5a503be
            Target Port SAS Address: 5000c5000d2da7be
          Expander SAS Address(Tier 2); 5000c5000d2da823
            Target Port SAS Address: 50800201a5a503be
            Target Port SAS Address: 5000c5000d2da7be

Example 10 Listing Target Port Information

The following command lists all target ports discovered on the host.

# sasinfo target-port
Target Port SAS Address: 5000c5000bae4009
Target Port SAS Address: 5000c5000baef4b1
Target Port SAS Address: 5000c5000bae3fe1
Target Port SAS Address: 5000c5000bae49d9
Target Port SAS Address: 5000c5000bae36c5

Example 11 Listing Target Port Information with Topology Details

The following command lists all target ports with the HBA port and expander that they are connected to.

# sasinfo target-port -v
Target Port SAS Address: 5000c5000bae4009
  Type: SAS Device
  HBA Port Name: /dev/cfg/c7
    Expander Device SAS Address: 500e004aaaaaaa3f
  HBA Port Name: /dev/cfg/c5
    Expander Device SAS Address: 500e004aaaaaaa3f
Target Port SAS Address: 5000c5000baef4b1
  Type: SAS Device
  HBA Port Name: /dev/cfg/c7
    Expander Device SAS Address: 500e004aaaaaaa3f
  HBA Port Name: /dev/cfg/c5
    Expander Device SAS Address: 500e004aaaaaaa3f
Target Port SAS Address: 5000c5000bae3fe1
  Type: SAS Device
  HBA Port Name: /dev/cfg/c7
    Expander Device SAS Address: 500e004aaaaaaa3f
  HBA Port Name: /dev/cfg/c5
    Expander Device SAS Address: 500e004aaaaaaa3f
Target Port SAS Address: 5000c5000bae49d9
  Type: SAS Device
  HBA Port Name: /dev/cfg/c7
    Expander Device SAS Address: 500e004aaaaaaa3f
  HBA Port Name: /dev/cfg/c5
    Expander Device SAS Address: 500e004aaaaaaa3f
Target Port SAS Address: 5000c5000bae36c5
  Type: SAS Device
  HBA Port Name: /dev/cfg/c7
    Expander Device SAS Address: 500e004aaaaaaa3f
  HBA Port Name: /dev/cfg/c5
    Expander Device SAS Address: 500e004aaaaaaa3f

Example 12 Listing Target Ports with SCSI Information

The following command lists all target port details, including SCSI information for each target port.

# sasinfo target-port -s 5000c5000bae4009
Target Port SAS Address: 5000c5000bae4009
   Type: SAS Device
        HBA Port Name: /dev/cfg/c7
            Expander Device SAS Address: 500e004aaaaaaa3f
                LUN : 0
                  OS Device Name : /dev/rdsk/c6t5000C5000BAE400Bd0s2
                  Vendor:   Sun
                  Product:  J4400
                  Device Type: Disk
        HBA Port Name: /dev/cfg/c5
            Expander Device SAS Address: 500e004aaaaaaa3f
                LUN : 0
                  OS Device Name : /dev/rdsk/c6t5000C5000BAE400Bd0s2
                  Vendor:   Sun
                  Product:  J4400
                  Device Type: Disk

Example 13 Listing the Logical Units

The following command lists the logical units on a host.

# sasinfo logical-unit
OS Device Name: /dev/rdsk/c4t50020F2300B4904Ed0s2
OS Device Name: /dev/rdsk/c4t50020F230000B4AFd0s2

Example 14 Listing Additional Information on Logical Units

The following command displays additional logical unit information using the -v option for device /dev/rmt/On.

# sasinfo lu -v
OS Device Name: /dev/rdsk/c4t50020F2300B4904Ed0s2
   HBA Port Name: /dev/cfg/c1
     Target Port SAS Address: 50020f2300b4904e
        LUN: 0
   Vendor: Sun
   Product: J4400
   Device Type: Disk
OS Device Name: /dev/rdsk/c4t50020F230000B4AFd0s2
   HBA Port Name: /dev/cfg/c1
     Target Port SAS Address: 50020f230063100b
        LUN: 0
   Vendor: Sun
   Product: J4400
   Device Type: Disk

Attributes

See attributes(5) for descriptions of the following attributes:

ATTRIBUTE TYPE
ATTRIBUTE VALUE
Availability
system/storage/sas-utilities
Interface Stability
Committed

See Also

attributes(5)